Infusion Pump
infusion pump
Infusion Pump VP1
Features:
1. Compatible with universal infusion set
2. High accuracy of ±3% after correct calibration
3. Three working modes: Rate Mode, Time Mode, Volume Mode
4. With more than 5000 history events can be recorded in the pump
5. Adjustable KVO rate 0.1~5.0 ml/h
6. Brightness could be adjustable to adapt the clinical use of the environment
CE Marked ISO13485
Technical Specifications of Infusion pump
PARAMETER | SPECIFICATION |
Fit IV tubes | Can be used with any brand IV set after exactly calibration |
Pump Type | Peristaltic finger pump |
Accuracy | ±3% |
Delivery rate range | 0.1ml/h~1200ml/h (0.1ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) (rate range could be OEM: 0.01ml/h~1200 ml/h) |
Delivery time range | 00h01min~99h59min (1 min step) |
Volume limit range: | 0.0-9999ml (1 ml step) |
Total Volume Range | 0.0-9999ml (1 ml step) |
Purge Rate | 600.0ml/h |
KVO Rate | 0.1~5.0ml/h. Programmable and adjustable |
Occlusion pressure | Three level setting LOW, MEDIUM or HIGH |
Alarms | Near empty, IV set empty, Volume complete (when limit volume is set), Occlusion, Operation error, Low battery, device failures. Three levels of alarm volume LOW, MEDIUM or HIGH |
Dose Mode | Volume:0.1-999.9ml(0.1ml step) Dose unit: ng/kg/min,ug/kg/min,mg/kg/min,g/kg/min,ug/kg/h, mg/kg/h,g/kg/h,ug/min,mg/min,g/min,ug/h,mg/h,g/h,U/min,U/h,IU/h,U/kg/h,ml/h |
Bolus function | Bolus rate:0.1~1200ml/h,Bolus volume:1.0~100ml Programmable and adjustable, Automatic/Manual bolus available |
Drug library Mode | 10 categories of drugs, amounts to 1030 kinds of drug names, 17kinds of dose units, such as ug/kg/min, mg/kg/min,etc. Makes drug dispensing more convenient and safer. (Available for VP3 only) |
Sequential mode | Available for VP3 only |
Interface | RS-232 |
Brightness | 1~10 levels can be selected |
History records | 5000 events stored can be checked and downloaded |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz; DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 12 hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF,IPX4 |
Dimension /N.W | 120mm*100mm*215mm , 1.8kg |
Packing size/G.W | 300mm*260mm*160mm, 2.5KG |
Infusion Pump with Drug Library VP3
Features:
1. Delivery range: 0.1ml/h~1200ml/h.
2. High accuracy ±3%after correct calibration
3. Five work modes: Rate Mode, Time Mode, Dose Mode, Sequential Mode and Drug library Mode.
4. Manual or Automatic Bolus /Purge/KVO function can be selected.
5. Vertical & Horizontal mounting clamp.
6. Anti-bolus system to reduce significantly after occlusion sudden release.
7. DPS dynamic pressure display.
8. 5000 events stored can be checked and downloaded.
9. Large LCD display, the brightness can be adjusted to adapt to the clinical use of the environment.
CE Marked ISO13485
Technical Specifications of Infusion pump (DPfusion VP3)
PARAMETER | SPECIFICATION |
Fit IV tubes | Can be used with any brand IV set after exactly calibration |
Pump Type | Peristaltic finger pump |
Accuracy | ±3% |
Delivery rate range | 0.1ml/h~1200ml/h (0.1ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) |
Delivery time range | 00h01min~99h59min (1 min step) |
Volume limit range: | 0.0-9999ml (1 ml step) |
Total Volume Range | 0.0-9999ml (1 ml step) |
Purge Rate | 600.0ml/h |
KVO Rate | 0.1~5.0ml/h. Programmable and adjustable |
Occlusion pressure | Three level setting LOW, MEDIUM or HIGH |
Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures. Three levels of alarm volume LOW, MEDIUM or HIGH |
Dose Mode | Volume:0.1-999.9ml(0.1ml step) Dose unit: ng/kg/min,ug/kg/min,mg/kg/min,g/kg/min,ug/kg/h,mg/kg/h, g/kg/h,ug/min,mg/min,g/min,ug/h,mg/h,g/h,U/min,U/h,IU/h,U/kg/h,ml/h |
Bolus function | Bolus rate:1.0~1200ml/h,Bolus volume:1.0~100ml Programmable and adjustable, Automatic/Manual bolus available |
Drug library Mode | 10 categories of drugs, amounts to 1030 kinds of drug names, 17kinds of dose units, such as ug/kg/min, mg/kg/min,etc. Makes drug dispensing more convenient and safer. (Available for VP3 only) |
Sequential mode | Available for VP3 only |
Interface | RS-232 |
Brightness | 1~10 levels can be selected |
History records | 5000 events stored can be checked and downloaded |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz; DC Power supply: 12~15V, power>15W; Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 12 hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF,IPX4 |
Dimension /N.W | 120mm*100mm*215mm , 1.8kg |
Packing size/G.W | 300mm*260mm*160mm, 2.5KG |